Sign-up for a free webinar

Monnit Industrial Wireless Accelerometer - G-Force Max and Avg

  • Monnit Industrial Wireless Accelerometer - G-Force Max and Avg

Also Available As:

Information

Price
$199.00
Format
Frequency
900 MHz
Part#
MNS-9-IN-AC-GM-SOL
Function
Power
Antenna

Monnit wireless accelerometers can be used in a host of applications where knowing impact, vibration, inclination, etc. is required.

The wireless accelerometer - G-Force max & avg sensor samples at 800 Hz over a 10 second period, and reports the measured MAXIMUM value for each axis in g-force and the AVERAGE measured g-force on each axis over the same period, for all three axes. This sensor reports in every 10 seconds with this data. Other sampling periods can be configured , down to one second and up to 10 minutes*. The data reported is useful for tracking periodic motion. Sensor data is displayed as Max X: 0.125 Max Y: 1.012 Max Z: 0.015 Avg X: 0.119 Avg Y: 1.005 Avg Z: 0.007.

Add to Cart
Set Your Location
Required to add products to your cart.

Product Description

Monnit wireless accelerometers can be used in a host of applications where knowing impact, vibration, inclination, etc. is required.

The wireless accelerometer - G-Force max & avg sensor samples at 800 Hz over a 10 second period, and reports the measured MAXIMUM value for each axis in g-force and the AVERAGE measured g-force on each axis over the same period, for all three axes. This sensor reports in every 10 seconds with this data. Other sampling periods can be configured , down to one second and up to 10 minutes*. The data reported is useful for tracking periodic motion. Sensor data is displayed as Max X: 0.125 Max Y: 1.012 Max Z: 0.015 Avg X: 0.119 Avg Y: 1.005 Avg Z: 0.007.

Monnit Industrial Sensors come in an IP65, NEMA 4X, CE rated, sealed, and weatherproof enclosure. They are powered by a single, replaceable, Industrial grade 3.6 V battery (included).

An optional solar powered version is also available. The solar powered version includes a Lithium Iron Phosphate rechargeable battery in conjunction with a solar power cell to keep the battery charged and at optimal capacity. If there is no light present at the solar cell, the battery alone could continue to power the sensor for up to 5 years.


Notes: 

These accelerometers do not "stream" continuous data. Please reference the data sheet for further information.


Product Features

  • Measures G-Force Max & Avg
  • 4096 count/g Sensitivity

  * Actual range may vary depending on environment.
** Battery life is determined by sensor reporting frequency and other variables.


What does this wireless sensor's data look like in software?

Accelerometer - G-Force Max and Avg - Data View in Software

What's in the box?

  • Wireless Sensor
  • Mounting Hardware
  • 3V Industrial Battery (Pre-Installed)
  • Solar Cell
  • Rechargeable 3V Industrial Battery (Pre-Installed)
  • SMA Antenna
 

Accelerometer Specifications

Sensitivity 4096 count/g
Sensitivity Range ± 2.0 g
Measurement Accuracy ± 2.5 %
Minimum G Force to Turn On/Wake Up 0.050 g - 0.100 g
Fastest Update Interval/Heart Rate in Any Configuration 1 Minute Sampling Rate: 500 Samples/Sec.
Current Consumption 0.7 µA (sleep mode)
2mA (radio idle/off mode)
2mA (measurement mode)
25mA (radio RX mode)
35mA (radio TX mode)
Bandwidth for Data Measurement 800 Hz
 

Industrial Specifications

Dimension 3.7 in x 2.32 in x 1.38 in
Max Operating Temperature -40° to 85°C (-40° to 185°F)
Device Range 300 - 350 ft. non-line-of-sight device range*
Supply Voltage 2.0 - 3.6 V
Battery Type Replaceable 3.6V, 1800mAH (single AA sized)
Optimal Battery Operating Temperature +10°C to +50°C (+50°F to +122°F)
Battery Life Up to 7 Year Battery Life.**
Solar Power Option 3.0 VDC Solar Panel
600 mAH Rechargeable Battery (>2000 Charge Cycles - 80% of Initial Capacity)
Charging Temperature Range: 0° to 45°C (32° to 113°F)
Max Temperature Range: -20° to 60°C (-4° to 140°F)
Enclosure Material IP65, NEMA 4X, CE rated, sealed, weatherproof enclosure
UL Rating UL Listed to UL508-4x specifications (File E194432)
 

900 MHz Specifications

Operating Frequency 900 MHz Operating Frequency
Certifications Complies with Part 15 of the FCC Rules. (FCC ID: ZTL-RFSC1)
Complies with Industry Canada standards. (IC: 9794A-RFSC1)
Specifications Image

Contact us for volume quantity purchases of RoHS compliant product.


Suggested Application Uses for This Sensor

  • Inclination and vibration testing
  • Assembly line monitoring
  • Orientation sensing
  • Smart machines, smart structures and smart materials
  • Impact load sensing