Pressure Sensor Specifications |
|
|
|
Performance |
0.7% BFSL Accuracy |
|
|
Storage Temperature |
-40 to 221ºF (-40 to 105ºC) |
|
|
Operating Temperature |
-40 to 185ºF (-40 to 85ºC) |
|
|
Thermal Effect on Reading |
2% per 100 ºF |
|
|
Noise Immunity |
20V/m (meets CE heavy industrial) |
|
|
Media |
Gas, Liquid or Vapor |
|
|
Electrical Protection |
Reverse polarity 75Vdc, Over-voltage 60 Vdc, and short-circuit protection |
|
|
Vibration |
5g's from 50 to 2000Hz. |
|
|
Humidity |
95% non-condensing |
|
|
Response Time |
Less than 2 ms (electronics) |
|
|
Wake-up Time: |
Less than 2 ms |
|
|
Insulation |
1 Meg ohm at 200 Vdc |
|
|
Wire Length: |
1 Meter shielded cable (between gauge and wireless unit) |
|
|
Dial Size |
2 1/2" (63 mm) |
|
|
Gauge Accuracy |
1.6% full-scale Grade A (63mm) |
|
|
Process Connection |
¼" NPT-Male Standard |
|
|
Proof Pressure |
0 to 160 psi = 120% of full scale |
|
|
Burst Pressure |
0 to 160 psi = 10x of full scale |
|
|
Window |
Polycarbonate or Safety Glass |
|
|
Case |
304 Series Stainless Steel |
|
|
Socket and Tube |
316 Series Stainless Steel |
|
|
Gauge Movement |
Suppressed Stop Movement for True Electrical Zero Reading |
|