Monnit wireless voltage meters are capable of measuring the voltage off another device, battery, or sensor. This sensor is capable of measuring voltage up to 50 VDC by connecting the leads on the sensor to the positive and ground terminals of the device being measured.
Examples of interfacing devices include, but are not limited to: Strain Gauge, Pressure Transducer, RTD, Thermistor, or Thermocouple, Piezo Electric sensors, Photoresistor, Industrial Accelerometer, any kind of variable resistor, any kind of sensor that outputs a voltage, etc. If the device being measured is passive, the user must supply their own excitation voltage, as the Monnit sensor is really just a “voltage observer”. Cannot be used for AC voltage measurement.
WARNING: Use caution when interfacing to the Monnit Wireless Voltage Meter. Negative voltages, any kind of AC Voltages, or DC Voltage exceeding 75V WILL DAMAGE the electronics of the Monnit Wireless Sensor. Monnit is not responsible for troubleshooting, replacing or reimbursing damages incurred by disregarding this warning.
* Actual range may vary depending on environment.
** Battery life is determined by sensor reporting frequency and other variables.
Voltage Meter Specifications |
|
Full Scale Voltage | 0 - 50 VDC |
Absolute Maximum Voltage | 75 VDC |
Resolution | 0.025 VDC |
Conversion Time | 228 µs |
Accuracy | +/- 3% FS |
User Calibrated Accuracy | +/- 1% FS |
Weight | 4.0 oz. |
Coin Cell Specifications |
|
Battery Type | Replaceable 3.0V Coin Cell Battery |
Dimension | 1.775 in x 1.04 in x 0.785 in |
Max Operating Temperature | -20°C to +60°C (-4° to +140°F) |
Optimal Battery Operating Temperature (Coin Cell) | +10°C to +50°C (+50°F to +122°F) |
Supply Voltage | 2.0 - 3.6 V (Single CR2032 Coin Cell Battery) |
Device Range | 250 - 300 ft. non-line-of-sight device range* |
Battery Life | At 1 hour heartbeat setting, coin cell battery will typically last ~ 1-2 Years. ** |
Enclosure Technology | Monnit PinchPower™ Wireless Sensor Enclosures |
Enclosure Material | ABS |
900 MHz Specifications |
|
Operating Frequency | 900 MHz Operating Frequency |
Certifications | Complies with Part 15 of the FCC Rules. (FCC ID: ZTL-RFSC1) Complies with Industry Canada standards. (IC: 9794A-RFSC1) |