• ALTA Wireless 0-20 mA Current Meter - AA Battery Powered
ALTA Wireless 0-20 mA Current Meter - AA Battery Powered

$110.00
Part #
MNS2-8-W2-MA-020
Region | Frequency
Not Selected - * Region Required
Quantity
Customize

Related Products

Standard (Generation 1) Products

Description

Monnit's ALTA wireless 0-20mA current meters are capable of measuring the current off another device or sensor, up to 20mA (DC), by connecting the leads of the sensor to the positive and ground terminals of the device being measured. Examples of interfacing devices include, but are not limited to: Current transducers (CTs) with outputs up to 20 mA, pH sensor, dissolved oxygen sensor, pressure sensor, magnetic flow meters, velocity or acceleration sensors, industrial vibration sensors, industrial accelerometers, any kind of sensor that specifies the output is in (mA) within the range of 0 – 20.

Explore ALTA Standout Features



  WARNING: Use caution when interfacing to the Monnit 0-20mA Current meter. Negative voltages, AC Voltages , DC Voltage exceeding 3.6V CAN DAMAGE the electronics of the wireless sensor. Monnit is not responsible for troubleshooting, replacing or reimbursing damages incurred by disregarding this warning.

Features

  • Interfaces with sensors between 0-20 mA.

  * Actual range may vary depending on environment.
** Battery life is determined by sensor reporting frequency and other variables.


Data Snapshot

Wireless 0-20 mA Current Meter - Data View in Software

In the Box

  • Wireless Sensor
  • Mounting Hardware
  • 2 x AA Batteries
 

0-20 mA Current Meter Specifications

Resolution ~ 0.01 mA (11-bit single ended)
Accuracy Uncalibrated: 0.7mA, 0.35mA typical
Caibrated: 0.05mA
Conversion Time 228 µs
Full Scale Voltage 0 - 20 mA
Weight 3.7 oz.
 

Variation Specifications

Security Encrypt-RF® (256-bit key exchange and AES-128 CTR)
 

ALTA AA Specifications

Battery Type 2 Replaceable AA 1.5 V Batteries
Dimension 4.375 in x 2.470 in x 1.12 in
Supply Voltage 2.0 - 3.8 V (2 x AA 1.5V Batteries or Optional Power Supply)
Battery Life At 1 hour heartbeat setting, included AA batteries will typically last 6-8 Years. **
Max Operating Temperature Using AA Alkaline -18°C to 55°C (0°F to 130°F)
Max Operating Temperature Using AA Lithium -40°C to 60°C (-40°F to 140°F)
Optimal Battery Operating Temperature +10°C to +50°C (+50°F to +122°F)
Enclosure Material ABS
 

ALTA 868 MHz Specifications

Operating Frequency 868 MHz Operating Frequency
Certifications CE Certified. Tested and found to comply with: EN 300 220-2 V3.1.1 (2017-02), EN 300 220-2 V3.1.1 (2017-02) and EN 60950.
Security Encrypt-RF® (Diffie-Hellman Key Exchange + AES-128 CBC)
Device Range Device Range Up to 1,200 ft. non-line-of-sight, wireless device range*
Specifications Image

Suggested Application Uses for This Sensor

  • Current transducer monitoring
  • pH sensor integration
  • Dissolved oxygen sensor integration
  • Pressure sensor integration
  • Magnetic flow sensor integration