• ALTA Industrial Wireless Voltage Detection - 200 VDC
ALTA Industrial Wireless Voltage Detection - 200 VDC

$215.00
Part #
MNS2-9-IN-VD-200
Region | Frequency
Not Selected - * Region Required
Product Variations
Quantity
Customize

Standard (Generation 1) Products

Description

The Monnit Voltage Detector - 200 VDC detects the presence or absence of electricity. It is intended for use on battery or other DC sources, up to 200 Volts. Not intended for use with AC Voltages. It is perfect for batteries, adapters, solar equipment, vehicles or machinery, and any other electrical appliance monitoring. The sensor triggers on voltage presence to voltage Absence and vice versa. The data is displayed as "Voltage Detected" or "No Voltage".

Explore ALTA Standout Features



  * Actual range may vary depending on environment.
** Battery life is determined by sensor reporting frequency and other variables.


Data Snapshot

Wireless Voltage Detection - 200 VDC - Data View in Software

In the Box

  • Wireless Sensor
  • Mounting Hardware
  • 3V Industrial Battery (Pre-Installed)
  • SMA Antenna
 

Voltage Detection Sensor Specifications

Maximum Rated Input Voltage 200.0 Volts
Minimum Rated Input Voltage -200.0 Volts
Voltage Detection Threshold Present above ~2 VDC, Absent below ~1.8 VDC (Indeterminant from 1.8 to 2 VDC)
Trigger Transmits data upon state change
Open Circuit Reading Voltage absent
Response Time ~2 Seconds
Lead Wire Length 2 Wires, 1 ft (12 in), Red (+), Black (-), 22 AWG
 

ALTA Industrial Specifications

Supply Voltage 2.0 - 3.8 VDC
Battery Type Replaceable 3.6V, 1800mAH (single AA sized)
Battery Life Up to 10 Year Battery Life.**
Max Operating Temperature -40° to 85°C (-40° to 185°F)
Optimal Battery Operating Temperature +10°C to +50°C (+50°F to +122°F)
Solar Power Option 3.0 VDC Solar Panel
600 mAH Rechargeable Battery (>2000 Charge Cycles - 80% of Initial Capacity)
Charging Temperature Range: 0° to 45°C (32° to 113°F)
Max Temperature Range: -20° to 60°C (-4° to 140°F)
Enclosure Material IP65, NEMA 4X, CE rated, sealed, weatherproof enclosure
UL Rating UL Listed to UL508-4x specifications (File E194432)
Dimension 3.7 in x 2.32 in x 1.38 in
 

ALTA 900 MHz Specifications

Operating Frequency 900 MHz Operating Frequency
Certifications Complies with Part 15 of the FCC Rules. (FCC ID: ZTL-G2SC1)
Complies with Industry Canada standards. (IC: 9794A-G2SC1)
Device Range Device Range Up to 1,200 ft. non-line-of-sight, wireless device range*
Security Encrypt-RF® (Diffie-Hellman Key Exchange + AES-128 CBC)
Specifications Image

Suggested Application Uses for This Sensor

  • Appliance monitoring
  • Sprinkler system monitoring
  • HVAC system monitoring
  • Line power monitoring
  • Power coupling monitoring
  • Power supply monitoring
  • Sump pump monitoring