* Actual range may vary depending on environment.
** Battery life is determined by sensor reporting frequency and other variables.
Resistance Sensor Specifications |
|
Resistive Range (in Ohms) | 0 – 145000 |
Specific Resistive Ranges (in Ohms) | 0 – 530, 530 – 3500, 3500 – 27200, 27200 - 145000 |
Resolution | 2047 Unique Values Per Specific Range (11 bit): ~.25, ~1.71, ~13.3, ~70.8. |
Accuracy | +/- 3% FS of Specific Range |
User Calibrated Accuracy | +/- 1.5% FS of Specific Range |
Lead Wire Length | 1 ft. ( 12 in.) |
Variation Specifications |
|
User Calibrated Pressure Accuracy | +/- 2% FS of Specific Range |
Weight | 3.1 oz. (87.88 g) with 3 ft. (0.91 m) lead |
ALTA AA Specifications |
|
Battery Type | 2 Replaceable AA 1.5 V Batteries |
Dimension | 4.375 in x 2.470 in x 1.12 in |
Supply Voltage | 2.0 - 3.8 V (2 x AA 1.5V Batteries or Optional Power Supply) |
Battery Life | At 1 hour heartbeat setting, AA batteries will last up to 10 years.** |
Max Operating Temperature Using AA Alkaline | -18°C to 55°C (0°F to 130°F) |
Max Operating Temperature Using AA Lithium | -40°C to 60°C (-40°F to 140°F) |
Optimal Battery Operating Temperature | +10°C to +50°C (+50°F to +122°F) |
Enclosure Material | ABS |
ALTA 900 MHz Specifications |
|
Operating Frequency | 900 MHz Operating Frequency |
Certifications | Complies with Part 15 of the FCC Rules. (FCC ID: ZTL-G2SC1) Complies with Industry Canada standards. (IC: 9794A-G2SC1) |
Device Range | Device Range Up to 1,200 ft. non-line-of-sight, wireless device range* |
Security | Encrypt-RF® (Diffie-Hellman Key Exchange + AES-128 CBC) |