• ALTA Industrial Differential Air Pressure Sensor
ALTA Industrial Differential Air Pressure Sensor

$418.00
Part #
MNS2-9-IN-PS-DP
Region | Frequency
Not Selected - * Region Required
Product Variations
Quantity
Customize

Standard (Generation 1) Products

Description

The ALTA industrial wireless differential pressure sensor measures the pressure difference between two input ports and transmits the measurement to iMonnit. When viewing the sensor from the top, the right inlet port is the negative or low side pressure input. When the pressure on this port is greater than the left port the sensor produces a negative pressure reading. When the pressure is greater on the left port the sensor produces a positive pressure reading.

Explore ALTA Standout Features



Features

  • Measurement range: -500 Pa to 500 Pa
  • Calibrated and temperature compensated

  * Actual range may vary depending on environment.
** Battery life is determined by sensor reporting frequency and other variables.


Data Snapshot

Differential Air Pressure Sensor Data in Software

In the Box

  • USB Cable
  • Wireless Sensor
  • Mounting Hardware
  • 3V Industrial Battery (Pre-Installed)
  • SMA Antenna
 

Pressure Range -500 Pa to 500 Pa
Allowable Overpressure 100 kPa
Rated Burst Pressure 500 kPa
Max Humidity for Long-Term Exposure 40°C dew point
Accuracy 3% of reading +/- 0.1 Pa
Span Repeatability 0.5% of reading
Span Shift Due to Temperature Variation < 0.5% of reading per 10°C
Offset Stability < 0.05 Pa/year
Calibrated For Air, N2
Media Compatibility Air, N2, O2, non-condensing
 

Variation Specifications

Supply Voltage 2.7–3.8 VDC (3.0–3.8 VDC using power supply)
 

ALTA Industrial Specifications

Supply Voltage 2.0 - 3.8 VDC
Battery Type Replaceable 3.6V, 1800mAH (single AA sized)
Battery Life Up to 10 Year Battery Life.**
Max Operating Temperature -40° to 85°C (-40° to 185°F)
Optimal Battery Operating Temperature +10°C to +50°C (+50°F to +122°F)
Solar Power Option 3.0 VDC Solar Panel
600 mAH Rechargeable Battery (>2000 Charge Cycles - 80% of Initial Capacity)
Charging Temperature Range: 0° to 45°C (32° to 113°F)
Max Temperature Range: -20° to 60°C (-4° to 140°F)
Enclosure Material IP65, NEMA 4X, CE rated, sealed, weatherproof enclosure
UL Rating UL Listed to UL508-4x specifications (File E194432)
Dimension 3.7 in x 2.32 in x 1.38 in
 

ALTA 900 MHz Specifications

Operating Frequency 900 MHz Operating Frequency
Certifications Complies with Part 15 of the FCC Rules. (FCC ID: ZTL-G2SC1)
Complies with Industry Canada standards. (IC: 9794A-G2SC1)
Device Range Device Range Up to 1,200 ft. non-line-of-sight, wireless device range*
Security Encrypt-RF® (Diffie-Hellman Key Exchange + AES-128 CBC)
Specifications Image

Suggested Application Uses for This Sensor

  • Building / Room Pressure
  • Air Flow
  • Variable Air Volume Filter Status
  • Duct Pressure
  • Clean Rooms
  • Hospitals
  • Fume Hoods
  • Computer Rooms
  • And many more...