The AC Voltage Detection Sensor notifies of the presence or absence of electricity. It is intended for use on devices using supply power from 24 - 500 VAC. Not intended for voltages higher than 500 VAC and also not intended for use with DC sources. Perfect for HVAC systems, sprinkler systems, sump pumps and any other type of electrical appliance monitoring. This sensor triggers on the state change from presence to absence of voltage and vice versa. The data is displayed as either "No Voltage" or "Voltage Detected".
* Actual range may vary depending on environment.
** Battery life is determined by sensor reporting frequency and other variables.
Voltage Detection Sensor Specifications |
|
Absolute Maximum Voltage | 600 VACrms / 850 VDC |
Minimum Voltage Detected | -850 VDC |
Accuracy | +/- (1 VACrms + 3% of reading) |
Calibrated Accuracy with Appropriate Offset | +/- (.5 VACrms + 1.5% of reading) |
Response Time | 40 ms |
Supported Operation Modes | VACrms (root mean squared) Peak Voltage DC Voltage |
Resolution | .25 VACrms / .35 VDC/Peak Voltage |
Lead Wire Length | 2 Wires, 1 ft (12 in), Black (Hot), White (Neutral), 18 AWG (Custom lengths available upon request.) |
Weight | 4.0 oz. |
Variation Specifications |
|
Security | Encrypt-RF® (256-bit key exchange and AES-128 CTR) |
ALTA AA Specifications |
|
Battery Type | 2 Replaceable AA 1.5 V Batteries |
Dimension | 4.375 in x 2.470 in x 1.12 in |
Supply Voltage | 2.0 - 3.8 V (2 x AA 1.5V Batteries or Optional Power Supply) |
Battery Life | At 1 hour heartbeat setting, included AA batteries will typically last 6-8 Years. ** |
Max Operating Temperature Using AA Alkaline | -18°C to 55°C (0°F to 130°F) |
Max Operating Temperature Using AA Lithium | -40°C to 60°C (-40°F to 140°F) |
Optimal Battery Operating Temperature | +10°C to +50°C (+50°F to +122°F) |
Enclosure Material | ABS |
ALTA 433 MHz Specifications |
|
Operating Frequency | 433 MHz Operating Frequency |
Certifications | CE Certified. Tested and found to comply with: EN 300 220-2 V3.1.1 (2017-02), EN 300 220-2 V3.1.1 (2017-02) and EN 60950. |
Device Range | Device Range Up to 1,200 ft. non-line-of-sight, wireless device range* |
Security | Encrypt-RF® (Diffie-Hellman Key Exchange + AES-128 CBC) |