• ALTA Wireless Voltage Meters - 0-500 VAC - Commercial Coin Cell Powered
ALTA Wireless Voltage Meters - 0-500 VAC - Commercial Coin Cell Powered

$88.00
Part #
MNS2-9-W1-VM-500
Region | Frequency
Not Selected - Frequency not selected!
Product Variations
Quantity
Add to Cart
Frequency required to add to cart. Select
Customize

Related Products

Standard (Generation 1) Products

Product Description

Monnit wireless voltage meters are capable of measuring the voltage off another device, battery, or sensor. This sensor is capable of measuring voltage up to 500 VAC by connecting the leads on the sensor to the positive and ground terminals of the device being measured.

Examples of interfacing devices include, but are not limited to: Strain Gauge, Pressure Transducer, RTD, Thermistor, or Thermocouple, Piezo Electric sensors, Photoresistor, Industrial Accelerometer, any kind of variable resistor, any kind of sensor that outputs a voltage, etc. If the device being measured is passive, the user must supply their own excitation voltage, as the Monnit sensor is a “voltage observer”.

ALTA - Leading Enterprise Grade "Internet of Things" Solutions

ALTA sensors offer 3 to 4 times the range of standard sensor platforms, extending non-line-of-sight reach to an exceptional 1,200+ feet through walls (12-14 walls typical). Using Frequency-hopping Spread Spectrum (FHSS) also allows ALTA sensors to have better interference immunity from other wireless devices.

Superior power management provides ALTA sensors with almost twice the battery life of Monnit’s standard wireless sensors.

  • Coin cell sensors typically last 3+ years.
  • AA and Industrial sensors typically last up to 12+ years.
ALTA products employ Monnit's new Encrypt-RF® Security (256-bit Diffie Hellman key exchange and AES-128 CBC encryption for all sensor data messages), so security is maintained at all communication points from sensor to gateway, gateway to software, then back again.

Integrated on-board data storage allows ALTA sensors to store data messages if communication to a wireless gateway is disrupted (power outage, Internet outage, or out of range). Messages that can’t be delivered will be time-stamped and stored in memory (up to the last 512 messages) until communication with the gateway is restored, at which point the messages will all be transmitted.

Over-the-air updates allow ALTA products to be updated remotely if new fixes or features become available.



 

WARNING: Use caution when interfacing to the Monnit Wireless Voltage Meter. Negative voltages, any kind of AC Voltages exceeding 600V WILL DAMAGE the electronics of the Monnit Wireless Sensor. Monnit is not responsible for troubleshooting, replacing or reimbursing damages incurred by disregarding this warning.


Product Features

  • Max sensor input voltage up to 600 volts (will return a max of 500 volts in software)
  • Interfaces with devices and power supplies up to 500 VAC

  * Actual range may vary depending on environment.
** Battery life is determined by sensor reporting frequency and other variables.


What does this wireless sensor's data look like in software?

Monnit Wireless Voltage Meters - 500 VAC - Data View in Software

What's in the box?

  • Wireless Sensor
  • CR2032 - Coin Cell Battery
  • Mounting Hardware
 

Voltage Meter Specifications

Calibrated Accuracy with Appropriate Offset +/- (.5 VACrms + 1.5% of reading)
Response Time 40 ms
Resolution .25 VACrms / .35 VDC/Peak Voltage
Lead Wire Length 2 Wires, 1 ft (12 in), Black (Hot), White (Neutral), 18 AWG (Custom lengths available upon request.)
Weight 4.0 oz.
Absolute Maximum Voltage 600 VAC RMS
Supported Operation Modes VAC RMS (root mean squared)
Accuracy +/- (1 VAC RMS + 3% of reading)
Resolution 25 VAC RMS
 

Variation Specifications

Security Encrypt-RF® (256-bit key exchange and AES-128 CTR)
 

ALTA Coin Cell Specifications

Battery Type Replaceable 3.0V (CR2032) Coin Cell Battery
Dimension 2.0 in x 1.125 in x 0.875 in
Max Operating Temperature -7°C to +60°C ( 20°F to +140°F )
Optimal Battery Operating Temperature (Coin Cell) +10°C to +50°C ( +50°F to +122°F )
Supply Voltage 2.0 - 3.8 VDC
Battery Life At 1 hour heartbeat setting, coin cell battery will last up to 4 years. **
Enclosure Technology Monnit PinchPower™ Wireless Sensor Enclosures
Enclosure Material ABS
 

ALTA 900 MHz Specifications

Operating Frequency 900 MHz Operating Frequency
Certifications Complies with Part 15 of the FCC Rules. (FCC ID: ZTL-G2SC1)
Complies with Industry Canada standards. (IC: 9794A-G2SC1)
Device Range Device Range Up to 1,200 ft. non-line-of-sight, wireless device range*
Security Encrypt-RF® (Diffie-Hellman Key Exchange + AES-128 CBC)
Specifications Image

Suggested Application Uses for This Sensor

  • Appliance monitoring
  • Line power monitoring
  • Power coupling monitoring
  • Power supply monitoring
  • Sump pump monitoring