The Monnit Voltage Detector - 200 VDC detects the presence or absence of electricity. It is intended for use on battery or other DC sources, up to 200 Volts. Not intended for use with AC Voltages. It is perfect for batteries, adapters, solar equipment, vehicles or machinery, and any other electrical appliance monitoring. The sensor triggers on voltage presence to voltage Absence and vice versa. The data is displayed as "Voltage Detected" or "No Voltage".
* Actual range may vary depending on environment.
** Battery life is determined by sensor reporting frequency and other variables.
Voltage Detection Sensor Specifications |
|
Maximum Rated Input Voltage | 200.0 Volts |
Minimum Rated Input Voltage | -200.0 Volts |
Voltage Detection Threshold | Present above ~2 VDC, Absent below ~1.8 VDC (Indeterminant from 1.8 to 2 VDC) |
Trigger | Transmits data upon state change |
Open Circuit Reading | Voltage absent |
Response Time | ~2 Seconds |
Lead Wire Length | 2 Wires, 1 ft (12 in), Red (+), Black (-), 22 AWG |
Variation Specifications |
|
Weight | 3.9 oz. (111 g.) |
ALTA AA Specifications |
|
Battery Type | 2 Replaceable AA 1.5 V Batteries |
Dimension | 4.375 in x 2.470 in x 1.12 in |
Supply Voltage | 2.0 - 3.8 V (2 x AA 1.5V Batteries or Optional Power Supply) |
Battery Life | At 1 hour heartbeat setting, AA batteries will last up to 10 years.** |
Max Operating Temperature Using AA Alkaline | -18°C to 55°C (0°F to 130°F) |
Max Operating Temperature Using AA Lithium | -40°C to 60°C (-40°F to 140°F) |
Optimal Battery Operating Temperature | +10°C to +50°C (+50°F to +122°F) |
Enclosure Material | ABS |
ALTA 900 MHz Specifications |
|
Operating Frequency | 900 MHz Operating Frequency |
Certifications | Complies with Part 15 of the FCC Rules. (FCC ID: ZTL-G2SC1) Complies with Industry Canada standards. (IC: 9794A-G2SC1) |
Device Range | Device Range Up to 1,200 ft. non-line-of-sight, wireless device range* |
Security | Encrypt-RF® (Diffie-Hellman Key Exchange + AES-128 CBC) |