  • PoE•X Duct Temperature Sensor
PoE•X Duct Temperature Sensor

$179.00
Part #
MNS-P-C1-TS-DT-L08
Region | Frequency
Not Selected - * Region Required
Quantity
Options

Description

The Power-over-Ethernet (PoE) Duct Temperature Sensor uses an NTC thermistor with 8 ft. lead wires to accurately measure temperatures in duct work, while maintaining a sealed environment. Can be easily installed and mounted for long term use.

The Power-over-Ethernet (PoE) Sensor products measure various conditions (environmental, power, access). All devices come with flexible settings — including notifications, alerts, reports, and maps — can be customized in the iMonnit online sensor management interface.

No PoE infrastructure in your building? Plug the PoE•X Sensors into your Ethernet network and then power the sensors with the optional AC power supply.

Click here to view all Monnit Power over Ethernet Sensors.



Features

  • Probe temperature range of -40°C to +150°C ( -40°F to +302°F )
  • Accurate to +/- 1° C (+/- 1.8°F)
  • User Calibrated Accuracy +/- 0.25° C (±0.45°F @ 77°F)
  • UL listed plenum probe cable

Data Snapshot

Monnit duct temperature sensor data view in software
 

Duct Temperature Sensor Specifications

Thermistor Operating Range -40°C to +150°C ( -40°F to +302°F )
Accuracy @ 25°C +/- 1° C (±1.8°F @ 77°F)
User Calibrated Accuracy +/- 0.25° C (±0.45°F @ 77°F)
Time Constant @ 25°C 30 sec.
Lead Wire Length 8 ft ( 96 in.)
Cable Rating UL listed plenum cable
Weight 3.7 oz.
 

Variation Specifications

Hardware 10 / 100 Ethernet Controller
Operation Full- and Half-Duplex
Cross-Over Correction Automatic MDI / MDI-X
Protocols Supported DHCP, DNS, NTP, UDP, TCP, SNMP, Modbus TCP
Cable Connector RJ45
Device Memory Up to 50,000 sensor messages; varies based on sensor type. (Sensor messages will be stored in the event of Internet outage and transferred when connection is restored.)
Operating Temperature -20 to +60°C (-4 to 140°F)
RTD Temperature Range -200°C to +162°C ( -328°F to +325°F )
Dissipation Constant @ 25°C 2mW/°C
Data Rate Auto configures to best rate for maximum range.
IEEE Standard Compliance 802.3AF-2003 / 802.3AT-2009 Class 1
Response Time 20 seconds max
Input Power Supplementary Power Requirement
Storage Temperature: -15 to +85°C (5 to 185°F)

Suggested Application Uses for This Sensor

  • Air Duct Temperature Monitoring
  • HVAC Operation & Testing
  • Data Center Monitoring
  • Coolers & Freezers
  • Environmental Monitoring
  • Smart Machines & Smart Structures