Monnit wireless AC Current Meters measure the RMS current of an alternating current (AC) system using a current transformer (CT) that wraps around the "hot" wire of a two wire (hot, common, ground(optional)) power system. The sensor reports Minimum RMS current, maximum RMS current, average RMS current, and amp hours to the iMonnit system. The iMonnit system is capable of generating watt hour or kilowatt hour readings as well.
The standard version of this sensor is powered by two replaceable 1.5 V AA sized batteries (included with purchase). This sensor is also available with a line power option. The line powered version of this sensor has a barrel power connector allowing it to be powered by a standard 3.0 - 3.6 V power supply (Included with Line Power option upgrade). The line powered version also uses two standard 1.5 V AA batteries as backup for uninterrupted operation in the event of line power outage.
Power options must be selected at time of purchase, as the internal hardware of the sensor must be changed to support the selected power requirements.
WARNING: This AC current meter is for monitoring AC voltage only. Do Not Use with DC voltage.
* Actual range may vary depending on environment.
** Battery life is determined by sensor reporting frequency and other variables.
AC Current Meter Specifications |
|
Absolute Max CT Current | 50 Amps RMS (Arms) |
Maximum Accurate CT Current | 20 A rms |
Frequency Measurement Range | 50 – 100 Hz |
Accuracy | +/- 2% @ 2 to 20 Arms, +/- .07 Arms @ < 2 Arms |
Calibrated Accuracy with Appropriate Offset | +/- 1% @ 2 to 20 Arms, +/- .035 Arms @ < 2 Arms |
Offset Limits | -1.27 to + 1.27 Arms (default set to +.1 Arms) |
Measurement Resolution | ~.01 Arms |
Weight | 3.7 oz. |
AA Specifications |
|
Battery Type | 2 Replaceable AA 1.5 V Batteries |
Dimension | 4.375 in x 2.470 in x 1.12 in |
Sensing Element | 2.0 - 3.6 V (2 x AA 1.5V Batteries or Optional Power Supply) |
Device Range | 250 - 300 ft. non-line-of-sight device range* |
Battery Life | At 1 hour heartbeat setting, included AA batteries will typically last 3-4 Years. ** |
Max Operating Temperature Using AA Alkaline | -18°C to 55°C (0°F to 130°F) |
Max Operating Temperature Using AA Lithium | -40°C to 60°C (-40°F to 140°F) |
Optimal Battery Operating Temperature | +10°C to +50°C (+50°F to +122°F) |
Enclosure Material | ABS |
868 MHz Specifications |
|
Operating Frequency | 868 MHz Operating Frequency |
Certifications | CE Certified and Complies with CISPR 22:2008-09 / EN 55022:2010 - Class B and ETSI EN 300 220-2 V2.4.1 (2012-05) |